- Cleaning and/or Replacing the Chemical Injector Valve
 Level of Difficulty - Medium  Estimated Completion Time - minutes
KAIVAC - KAIVAC 1750

Tools Required
Tool 
Crescent wrench
Pliers-needle nose
Screwdriver-phillips
Wrench-Allen standard 1/2 in

Parts Required


Step Procedure & Parts & Tools
1 Locate the chemical knob on the control panel.

2 Using a 1/2 inch Allen wrench, loosen the set screw on the chemical knob.
Wrench-Allen standard 1/2 in

3 Pull the chemical knob to remove it.

4 Using a Phillips screwdriver, remove the four screws from the control panel.
Screwdriver-phillips

5 Pull the control panel up to access the brass knob.

6 Using a crescent wrench, remove the brass ring from the knob.
Crescent wrench

7 Locate the chemical injector valve.

8 Using needle pliers, squeeze the hose clamps to loosen them.
Pliers-needle nose

9 Using a wrench, remove the brass elbows from the chemical injector valve.
Crescent wrench

10 Remove the tip slowly and carefully so you don't lose the inner parts. Set aside the spring and ball.

11 Use a paper clip or small allen wrench to clean the tip. Reverse the process to re-install or replace the chemical injector valve.